Can Agentic Systems Close the Gap in Radiology with Production AI Tools?
Aubin Charley, Julien Khlaut, Charles Corbière, Pierre Manceron, Corentin Dancette, Léo Machado
arXiv:2611.09836v1Radiology is one of the clearest places where AI has already become clinically useful, but it has also exposed a hard truth: the field does not really need one model that does everything poorly. It needs a system that can read a study the way a radiologist does, by combining many specialized capabilities into one coherent report. That is the problem this paper tackles. A radiology exam begins with images, but it ends with a report that compresses a huge amount of information: what is normal, what is abnormal, how severe it is, whether it changed from prior studies, and what it means clinically. A chest CT, for example, is not just a lung nodule detector. It requires surveying the lungs, pleura, mediastinum, vessels, bones, and upper abdomen, and often measuring findings and comparing them with prior exams. Current AI tools usually cover only one narrow piece of that workflow. The paper starts from two existing families of radiology AI. The first is specialized tools: models for lung nodules, liver segmentation, calcium scoring, and similar tasks. These can be very good within their scope, but they only cover a small slice of what appears in a report. The second is generalist vision-language models that can generate fluent report text, but they often miss findings, hallucinate details, or measure inaccurately. In 3D CT report generation, they can also collapse into repetitive template-like text rather than truly analyzing the scan. A promising third direction is the agentic system: a large language model acts as an orchestrator, decides what to look for, calls tools, interprets their outputs, and then writes the report. This has worked in some narrow settings, but existing systems are usually built for one modality or one anatomy, with a fixed tool set. So the big question here is not whether a single tool can detect a lesion. It is whether an agentic system, using tools that already exist in the real world, can come close to comprehensive radiology reporting. To study that, the authors build a radiology agentic framework with a shared interface, inspired by the software idea behind the Model Context Protocol. The point is to standardize how an orchestrator discovers and calls tools, regardless of who built them. They also adopt a ReAct-style loop, where the model alternates between reasoning and acting: it thinks about what to do next, calls a tool, sees the result, and then decides the next step. Their framework has three layers. First are resources: patient context, prior studies, a whole-body anatomical reference frame from total-body segmentation, clinical guidelines, RadReport templates, the available tool catalog, and the study being interpreted. Second are tools, grouped into categories such as viewer interaction, multi-series operations, AI vision, quantification, dynamic analysis, longitudinal comparison, and clinical intelligence. Third is the orchestrator, which plans, calls tools, and writes a structured report. The orchestrator itself is not just one prompt. It is a pipeline. A context loader reads the patient record, retrieves priors, and identifies available tools. A planner turns the clinical indication and a report template into an ordered list of analysis steps, plus drafting steps that specify what anatomical regions and observation categories must be covered. A grouper then organizes those steps into tracks that can run in parallel, so independent series can be analyzed concurrently while steps that belong to the same lesion stay sequential. Then each track runs through a ReAct loop, calling tools one at a time and updating its conclusions. After that, an analyzer merges the tracks, reconciles discrepancies, and decides whether to continue, regroup, or replan. A reporter drafts the final report in the template structure, and a reviewer scores the draft against the findings used and can trigger one rewrite if the score is too low. The key experimental idea is to separate tool availability from tool error. To do that, tool outputs are simulated from the reference report. So if the system misses something, it is not because the detector made a mistake. It is because the tool was unavailable, the orchestrator did not call it, or the planning strategy was insufficient. That makes the study a clean test of the system design itself. The authors compare two catalogs. One is a tool-infinite catalog, where the orchestrator can request any plausible tool and any finding class it wants. The other is a catalog distilled from FDA-cleared radiology AI devices. They start from the FDA list of AI-enabled radiology devices, extract the output classes from public decision summaries, and consolidate them into a final catalog of 1,989 finding classes, each tied to the modalities on which it is cleared. In the cleared setting, the orchestrator can only request classes that are actually available for the study’s modality. They also vary the information given to the planner. In the realistic setting, the planner sees only the clinical indication and the template. In an oracle setting, it also sees the target report, which is controlled leakage and serves as a topline for how well the rest of the pipeline can execute when the plan is effectively written with knowledge of the answer. The evaluation uses PARROT, a multilingual corpus of fictional radiology reports spanning CT, MRI, radiography, and ultrasound, across chest, abdomen, head, and pelvis. They keep English reports with a clinical indication, and the main evaluation is on the subset that produced parseable outputs in all modes. Reports are matched to RadReport templates so that formatting differences do not dominate the comparison. For scoring, they use RadMatch, which breaks both the generated and reference reports into atomic findings and matches them at the finding level. It tracks whether a finding is normal or abnormal, whether measurements and longitudinal status are correct, and whether the anatomical entity matches. The headline metric is actionable recall: the fraction of reference findings at critical, urgent, or notable tiers that the generated report recovers. They also report actionable precision in held-out runs. The paper then does something especially useful: it attributes every missed finding in the realistic cleared setting to a cause. Each omission is judged against the catalog and the tool list. A finding can fail because no cleared class exists for that modality, because a relevant class was offered but not called, because a class-free tool that could have surfaced it was not invoked, because a new kind of tool would be needed, or because no imaging tool could reasonably find it at all. So what happens? With the cleared catalog and only the clinical indication, the orchestrator recovers under a third of clinically actionable findings. That is the central result. It says that today’s cleared tools, as a deployed ecosystem, leave a large gap if the goal is comprehensive reporting. Performance improves substantially with the tool-infinite catalog. That means the bottleneck is not just the orchestrator’s language ability; the breadth of available tools matters a lot. It improves further when the planner is given the target report. That tells us the planning stage itself is also a major constraint, because a better plan can guide the system toward the right tools and the right order of operations. The attribution analysis explains where the gap comes from. Most missed findings are in the catalog gap: they are classes that no cleared device offers for that study’s modality. But about a third are not due to missing tools at all. They are classes or tools that were available and simply were not called. That is an important distinction. It means the problem is not only that radiology AI lacks coverage; it is also that orchestration is not yet reliable enough to exploit the coverage that does exist. The authors then test a simple fix: add the most frequently missing tools. On held-out reports, this closes most of the gap to the tool-infinite catalog. But if instead you use a smaller orchestrator with the unlimited catalog, you lose the gain. In other words, tool availability and orchestration quality are complementary. You need both. That is the paper’s main lesson. The path to comprehensive AI-assisted radiology reporting is not just building larger models, and it is not just adding more point solutions. It is building a system architecture that can discover, call, and combine many tools effectively, while also expanding the tool catalog itself. There are some important limitations to keep in mind. First, the study uses simulated tool outputs derived from reference reports, so it isolates orchestration and catalog coverage rather than real model error. That is a strength for analysis, but it means the results are not a direct estimate of end-to-end clinical performance. Second, the cleared catalog is a snapshot of FDA-cleared devices and is used as a proxy for deployed tools; the authors explicitly do not make a regulatory claim. Third, the evaluation corpus consists of fictional reports, not real clinical cases, even though it is broad and multilingual. Fourth, the system relies on templates, structured planning, and an LLM orchestrator, so real-world performance will depend heavily on prompt design, tool reliability, and integration into clinical workflows. Still, the paper makes a strong conceptual contribution. It reframes radiology AI from “Can one model read the scan?” to “How much of a radiology workflow can an agentic system cover with the tools that actually exist?” And its answer is nuanced but clear: today’s ecosystem can do more than isolated models, but comprehensive reporting is still limited by both missing tools and imperfect orchestration. Closing the gap will require progress on both fronts at once.
Also spotted that day
Previous daily papers